<%NUMBERING1%>.<%NUMBERING2%>.<%NUMBERING3%> PRTG Manual: Remote Probe Setup via Device Tools

Directly install a remote probe by right-clicking a device in the device tree. This partially automatic installation mechanism is an alternative to installing a remote probe using the Remote Probe Installer. For a quick installation guide, see the Paessler Website: How to install a PRTG remote probe in 4 steps.

i_round_blueThis is an experimental feature. It might not work in all situations. In this case, see section Debugging.

i_podThis feature is not available in PRTG Hosted Monitor.

i_round_blueYou cannot install a remote probe on the local probe device or hosted probe device. The Remote Probe Setup via Device Tools is also not available for devices on remote probes. In this case, use the Remote Probe Installer.

i_round_redIf you run PRTG in a cluster, see Cluster and Remote Probes Outside the LAN.

Steps to Take

To install a remote probe directly from the device tree in the PRTG web interface, follow these steps:

Step 1: Meet the Requirements

To install a remote probe on a computer, make sure that you meet the following requirements.

  • The target computer runs the operating system Windows 7 or later.
  • The target computer is accessible through remote procedure call (RPC). This is usually the case when your PRTG core server and the target computer are located in the same LAN segment. Otherwise, open Windows services.msc on the target computer and start the RPC service.
  • Programs are allowed to communicate through your Windows Firewall. Open the settings of your firewall and select Allow an app through firewall. Mark the check box for Remote Service Management, and the check box Public in the corresponding line.
  • Connections between remote probes and the PRTG core server require port 23560. Make sure that on your PRTG core server side, this port is not blocked by firewall rules, and, on the remote probe side, the Transmission Control Protocol (TCP) port 23560 is open for outgoing connections as well.
    i_square_cyanIf you need to set a different port (not recommended), see the Knowledge Base: How can I customize ports for core-probe connections used by PRTG?

i_round_blueYour PRTG on premises or PRTG Hosted Monitor installations already include a local probe or hosted probe on the PRTG core server. This is why you cannot additionally install a remote probe on your PRTG core server system.

i_square_cyanFor more information on the requirements for remote probes, see section System Requirements.

Step 2: Prepare the PRTG Core Server

i_round_redBecause your remote probe needs to connect to your PRTG core server, PRTG needs to accept incoming remote probe connections. So, with PRTG on premises, first prepare your PRTG core server before you install the remote probe.

Edit the relevant settings in section Core & Probes. From the main menu in the PRTG web interface, select Setup | System Administration | Core & Probes to access the probe settings and go to the Probe Connection Settings.

Probe Connection Settings in System Administration

Probe Connection Settings in System Administration

Step 2.1: Probe Connection IPs

By default, a PRTG core server accepts connections from the Local Probe only (IP address 127.0.0.1). This setting is the most secure setting, but it does not allow any remote probes to connect to your PRTG core server.

To accept remote probes, select one of the following settings:

  • All IPs available on this computer: Any IP on your PRTG core server system accepts incoming probe connections.
  • Specify IPs: Specify selected IP addresses that accept incoming connections.

Step 2.2: Allow IPs

In the Allow IPs field, you can enter the IP address of the computer on which you want to install a remote probe. You can also enter the word any. This sets the PRTG core server to accept remote probe connections from any IP address.

i_round_redIf you use any, make sure that you only write the word in lower case. Any other variations are not valid.

Changing other settings is not required. For details about the fields for Access Keys, Deny IPs, and Deny GIDs, see section Core & Probes.

When you are done, click Save to save your settings.

i_round_redIf you change this setting, PRTG needs to restart the PRTG core server to apply your changes. After clicking Save, a dialog box appears that asks you to confirm the restart. Click OK to trigger the restart. During the restart, all users of the PRTG web interface, of PRTG Desktop, or of PRTG Apps for Mobile Network Monitoring are disconnected and reconnected.

i_round_blueTo edit the core–probe connection settings, you can also use the PRTG Administration Tool on your PRTG core server.

Cluster and Remote Probes Outside the LAN

i_round_redIf you run PRTG as a cluster and you want to run remote probes outside your local network, you have to make sure that your cluster nodes and the addresses they use are reachable from the outside. Check your cluster node settings under Cluster before you install a remote probe outside your local network. Enter valid addresses (Domain Name System (DNS) names or IPs) for both cluster nodes to reach each other and for remote probes to individually reach all cluster nodes. Remote probes outside your LAN cannot connect to your cluster nodes if they use local addresses.

If you already have a remote probe installed outside your LAN and the remote probe is disconnected because of this, follow these steps:

  1. Uninstall the remote probe.
  2. Update the cluster node settings with addresses that are reachable from outside your LAN.
  3. Restart your PRTG core servers.
  4. Install the remote probe again. It then obtains the IP address or DNS name entries that it can reach.

i_square_cyanSee also section Failover Cluster Configuration, section Remote Probes in a Cluster.

Step 3: Provide Credentials (Optional)

If you have not yet done so, add a device that represents the target computer on which you want to install the remote probe. Set the correct Windows credentials for this device.

  1. Open the device settings.
  2. In the Credentials for Windows Systems section, provide Domain or Computer Name, User Name, and Password for the target computer. You can also inherit the credentials from the settings of a parent object in the device tree.

i_round_redMake sure that this user account has administration rights on the target computer.

Step 4: Install the Remote Probe

  1. In the device tree, open the context menu of the target device.
  2. Select Device Tools | Install Remote Probe to open the install dialog in a new window.

i_round_blueThis option is only available for devices on the PRTG on premises local probe.

Remote Probe Installation Dialog

Remote Probe Installation Dialog

The install dialog includes four sections:

  • Experimental feature notice and short introduction
  • Details: Overview of the device like Device Name, Status, Priority, Parent Probe, Parent Group, and Sensors by State.
  • Prerequisites: Make sure that you meet the requirements listed here. If not, PRTG cannot start the installation process. Open requirements are highlighted in red.
Installation Unable to Start Because Prerequisites Are Not Met

Installation Unable to Start Because Prerequisites Are Not Met

  • Start Probe Installation: Time estimation for the installation and installation start button

If all prerequisites are met, you can install the remote probe on the target computer by clicking Install Remote Probe on "[device name]". Wait until the process has ended. If the installation is successful, the following message appears in the Start Probe Installation section: Done. Result is: OK.

i_round_blueEvery time you start an installation, PRTG automatically adds a new key to the field Access Keys in the Core & Probes settings, no matter if the installation has been successful or not.

Step 5: Approve the New Remote Probe

If the installation is successful, you receive further instructions after the result message. You also receive a new ToDo ticket.

Click Approve and auto-discover new probe to acknowledge the new remote probe and to instantly start an auto-discovery in this network. Click Approve new probe to acknowledge the new remote probe without running an auto-discovery. You can also discard the remote probe by clicking Deny.

i_round_redWhen you deny or remove a remote probe, this device's global ID (GID) is listed in the Deny GIDs field in the Core & Probes settings. Future probe connections from this device are automatically denied.

i_round_blueDenying the remote probe in the device tree does not uninstall the remote probe, but only denies access to the PRTG core server. The remote probe continues to run on the target system until you uninstall it manually.

Wait while the remote probe connects. Once the remote probe has connected, you can create groups, devices, and sensors to customize your monitoring via the new remote probe.

Debugging

  • Note that installing a remote probe directly from the device tree in the PRTG web interface is an experimental feature. This approach might not be possible in all situations.
  • Make sure you met all the requirements as described in step 1 such as the Windows Firewall settings.
  • If the quick installation procedure as described in this section does not work with your setup, manually install your remote probes via the Remote Probe Installer as described in section Install a Remote Probe.

More

i_square_blueKNOWLEDGE BASE

How can I customize ports for core-probe connections used by PRTG?

 

i_square_bluePAESSLER WEBSITE

How to connect PRTG through a firewall in 4 steps

How to install a PRTG remote probe in 4 steps

Add Remote Probe